In this article, torsional control has been studied in the plan-mass asymmetric vertical seismic isolation (VSI) system considering the three-dimensionally analytical model. In the 3D VSI, a structure is partitioned by vertical isolation planes into two inner and outer substructures interconnected by links for lateral response reduction. In an ideal analytical model of plan-mass asymmetric VSI, plan-wise distribution of damping and stiffness have been provided for more torsional control. Seismic responses of the non-classically 3D VSI were obtained by Runge-Kutta numerical method, considering a large number of isolation ratios. In this investigation, the mass and stiffness ratios of substructures are defined with respect to the original structure which provides a novel method of graphic presentation for analysis results. In this manner, contour graphs create comprehensive and worthwhile insight into the 3D VSI behavior and can also serve as a design tool for the preliminary design of the system. The results show that in the case that the inner substructure is the flexible one, torsional control is nearly effective in both substructures satisfactorily, regardless of plan-wise damping distribution. However, in the second case that is the outer flexible substructure, torsional control is nearly effective in the stiff substructure while the response in flexible substructure is satisfactory just in a limited range of isolation ratios.
In a vertical seismic isolation (VSI) system, an individual structure is partitioned in a vertical isolation plane into two dynamically different substructures interconnected by a mechanism. In this way, response reduction is expected in each substructure when compared to the original non-partitioned structure. In this study, the features of an SDOF with nonlinear viscous dampers (NVDs) subjected to harmonic loading have first been investigated, and a criterion has been proposed for evaluating their seismic behavior by comparing to that of linear viscous damper (LVD) based on damper force capacity. Then, by using a set of earthquakes with a wide range of dominant periods, and conducting a series of nonlinear time history analyses, the application of NVDs in the VSI has been thoroughly studied in regard to substructure displacement and acceleration response reduction. In these analyses, the interaction effect of isolation ratios and link parameters on response control of the VSI system was explored. The investigation of NVDs was carried out equating the viscous damper force in different velocity exponents with the corresponding LVD. Results did not indicate a preferable performance of NVDs over an LVD. Yet, employing appropriate link parameters proportional to mass and stiffness ratios could lead to satisfactory levels of seismic response reduction in cases of both types of dampers.
In vertical seismic isolation (VSI), a building is partitioned intentionally by vertical layers into two dynamically different substructures for seismic response reduction. Initially, a 1-story frame was partitioned into two substructures, interconnected by viscous and visco-elastic links, and seismic responses of the original and the vertically isolated structures (VIS) were obtained, considering a large number of stiffness and mass ratios of substructures with respect to the original structure. Color contour graphs were defined for presentation and investigation of large amounts of output results. Dynamic characteristics of the isolated structures were studied by considering the non-classical damping of the system, and then the effects of viscous and visco-elastic link parameters on the modal damping ratios were discussed. On this basis, three states of mass isolation, interactional state, and control mass were differentiated. Response history analyses were performed by Runge-Kutta numerical method. In these analyses, interaction of isolation ratios and link parameters, on response control of VIS was studied and the appropriate ranges for link parameters as well as the optimal ranges for isolation ratios were suggested. Results show that by using the VSI technique, seismic response reduction up to 50% in flexible substructure and even more in stiff substructure is achievable.
در این پژوهش، جداسازی لرزهای قائم یک ساختمان به دو زیرسازه با مشخصات دینامیکی متفاوت با هدف کاهش پاسخ لرزهای مورد مطالعه قرار گرفته است. برای این منظور یک قاب برشی با میراگر ویسکوز و ویسکوالاستیک به دو زیرسازه تفکیک شده و پاسخ لرزهای سازه اصلی و سازههای جداسازی شده قائم (س.ج.ق.) برای تعداد قابلتوجهی از نسبتهای جرم و سختی زیرسازهها نسبت به سازه اصلی، تحت تحریک زلزلههایی با پریود غالب کمتر از نیم ثانیه و بیشتر از نیم ثانیه محاسبه شده است. در این مطالعه دستگاه مختصات جداسازی و نمودارهای کانتوری معرفی شده که نحوه پاسخ لرزهای س.ج.ق. را بیان میکند و بر اساس آن سه حالت جداسازی جرمی، اندرکنشی و کنترل جرمی از هم تمیز داده شده است. همچنین اثر متقابل نسبتهای جداسازی و مشخصات میراگرهای ارتباطی شامل سختی و میرایی، بر کنترل پاسخ س.ج.ق. مورد بررسی قرار گرفته و محدودههای مناسبی از مشخصات میراگرها و همچنین محدودههای بهینه از نسبتهای جداسازی پیشنهاد شده است. در انتها تأثیر جداسازی در یک ساختمان برشی 5 طبقه مطالعه شده است. نتایج دلالت بر آن دارد که با بهکارگیری جداسازی قائم، کاهش پاسخ لرزهای تا 40 درصد در زیرسازه نرم و حتی بیشتر از آن در زیرسازه سخت قابل دستیابی است.
در جداسازی لرزهای قائم با اعمال صفحات جداساز قائم یک ساختمان به دو زیرسازه با مشخصات دینامیکی متفاوت با هدف کاهش پاسخ لرزهای جداسازی میگردد. در این مطالعه ابتدا ویژگیهای جداسازی قائم با میراگرهای خطی بررسی شده است. دستگاه مختصاتی بهعنوان مختصات جداسازی و نمودارهایی کانتوری که بیانگر نحوه پاسخ لرزهای سازههای جداسازی شده میباشد معرفی شده و بر اساس آن سه حالت جداسازی جرمی، اندرکنشی و کنترل جرمی از هم تمیز داده شده است. در ادامه رفتار میراگر ویسکوز غیرخطی در یک سازه یکدرجه آزاد تحت اثر بارگذاری هارمونیک مورد مطالعه قرار گرفته و معیاری برای مقایسه پاسخ لرزهای میراگرهای خطی و غیرخطی بر اساس ظرفیت نیروی میراگر پیشنهاد شده است. با انتخاب مجموعهای از رکوردهای زلزله با پریود غالب در محدودههای مختلف طیف شتاب و انجام تحلیلهای تاریخچه پاسخ غیرخطی، کاربرد میراگرهای ویسکوز غیرخطی در جداسازی قائم بهطور جامع مورد مطالعه قرار گرفته است. نتایج مطالعه دلالت بر این داشت که تکنیک جداسازی قائم یک روش کارآمد برای کاهش پاسخ لرزهای با هر دو میراگر ویسکوز خطی و غیرخطی با توان سرعت در محدوده 0.5≤α